Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1526324

RESUMO

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

2.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1526407

RESUMO

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

3.
Braz. dent. sci ; 26(4): 1-8, 2023. ilus, tab
Artigo em Inglês | BBO, LILACS | ID: biblio-1512140

RESUMO

Objective: To evaluate the biaxial flexural strength (BFS) of lithium disilicate (L), cemented on different substrates (epoxy resin - E and metal - M) with dual-cure resin cement (Rc) and zinc phosphate cement (Zc), not aged, thermally aged (TC) or thermo-mechanical aged (TC/MC). Material and Methods: Disks of L, E, and M were fabricated, and the cementation was performed according to the following groups: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Ten samples from each described group were tested in BFS, ten more samples were subjected to TC (1×104 cycles between 5 ºC and 55 ºC water), and the last 10 samples were subjected to TC/MC (MC: 1.2×106 cycles, 50 N, 3.8 Hz). The BFS test was performed and scanning electron microscopy (SEM) was performed to evaluate the failure mode. The effect of the cementation strategy (cement/substrate) was compared in each aging method and the effect of the aging method was evaluated for each cementation strategy by one-way ANOVA and Tukey post-hoc test (α=0.05). Results: The strength values were highest to M (237.8 ~ 463.9 MPa), in comparison to the E (41.03 ~ 66.76 MPa), despite aging and luting agent. Flexural strength data decreased after TC and TC/MC in groups cemented with Zc, but was stable when cemented with Rc. SEM analysis indicated that failure origins were located at the tensile surface of the L. Conclusion: Lithium disilicate discs cemented to the metallic substrate presented the highest biaxial flexural strength. The cementation with dual-cure resin cement did not decrease BFS after aging (AU)


Objetivo: Avaliar a resistência à flexão biaxial (BFS) do dissilicato de lítio (L), cimentado sobre diferentes substratos (resina epóxi - E e metal - M) com cimento resinoso dual (Rc) e cimento de fosfato de zinco (Zc), não envelhecido, submetido ao envelhecido térmico (TC) ou ao envelhecido térmico-mecânico (TC/MC). Material e Métodos: Foram confeccionados discos de L, E e M, e a cimentação foi realizada de acordo com os seguintes grupos: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Dez amostras de cada grupo descrito foram testadas em BFS, mais dez amostras foram submetidas à TC (1×104 ciclos de imersão em água entre 5 ºC e 55 ºC), e as últimas 10 amostras foram submetidas à TC/MC (MC: 1.2 ×106 ciclos, 50 N, 3.8 Hz). Foram realizados os testes de BFS e a microscopia eletrônica de varredura (MEV) para avaliar o modo de falha. O efeito da estratégia de cimentação (cimento/substrato) foi comparado em cada método de envelhecimento e o efeito do método de envelhecimento foi avaliado para cada estratégia de cimentação por ANOVA a um fator e teste post-hoc de Tukey (α=0,05). Resultados: Os valores de resistência foram maiores para M (237.8 ~ 463.9 MPa), em comparação com E (41.03 ~ 66.76 MPa), independentemente do envelhecimento e do agente cimentante utilizado. Os dados de resistência à flexão diminuíram após TC e TC/MC nos grupos cimentados com Zc, mas se mantiveram estáveis quando cimentados com Rc. A análise MEV indicou que a origem das falhas estava localizada na superfície de tração do L. Conclusão: Os discos de dissilicato de lítio cimentados ao substrato metálico apresentaram maior resistência à flexão biaxial. A cimentação com cimento resinoso dual não diminuiu o BFS após o envelhecimento (AU)


Assuntos
Envelhecimento , Cimentação , Resistência à Flexão
4.
RGO (Porto Alegre) ; 71: e20230020, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1449027

RESUMO

ABSTRACT Objective: This study assessed whether the use of a silane coupling agent influence the bond strength of two universal adhesives to ceramic or resin CAD/CAM blocks. Methods: Forty-eight samples were obtained from each resin nano-ceramic hybrid block (RCBs) and lithium disilicate ceramic blocks (LD). Samples were treated with silane with MDP (Monobond - S-MDP), silane without MDP (Prosil - PS), and no silane application (Control - Ctr) followed by universal adhesive with silane (UAS) and without silane (UA) (n=8). Three polyurethane tubes (1.5 mm of internal diameter) were positioned in each sample treated surface and filled with a dual cured resin cement. Bond strength was assessed by microshear bond strength test and failure analysis was performed for all samples. Results: For the RCBs, UAS presented the highest bond strength values (p=0.004). Silane application was not significant in bond strength values (p=0.444). For LD, silane application was significant in bond strength values (p<0.001), but the adhesive was not (p=0.066). Failure analysis showed high prevalence of adhesive failures for both substrates. Conclusion: A silane-containing universal adhesive promoted the best bond strength results to the resin nano-ceramic hybrid block. For bonding to a glass-ceramic CAD/CAM material, additional silane (without MDP) application presented the best results.


RESUMO Objetivo: Este estudo avaliou se o uso de um agente de união silano influencia na resistência de união de dois adesivos universais a blocos CAD/CAM cerâmicos ou resinosos. Métodos: Quarenta e oito amostras foram obtidas de blocos resinosos (RCBs) e cerâmicos de dissilicato de lítio (LD). As amostras foram tratadas com silano contendo: MDP (Monobond - S-MDP), silano sem MDP (Prosil - PS) ou sem aplicação de silano (Control - Ctr) seguido de adesivo universal com silano (UAS) ou sem silano (UA) (n=8). Três tubos de poliuretano (1,5 mm de diâmetro interno) foram posicionados em cada superfície tratada da amostra e preenchidos com um cimento resinoso dual. A resistência de união foi avaliada pelo teste de microcisalhamento e a análise de falha foi realizada para todas as amostras. Resultados: Para os RCBs, UAS apresentou os maiores valores de resistência de união (p=0,004). A aplicação de silano não foi significativa nos valores de resistência adesiva (p=0,444). Para LD, a aplicação de silano foi significativa nos valores de resistência de união (p<0,001), mas o adesivo não (p=0,066). A análise de falhas mostrou alta prevalência de falhas adesivas para ambos os substratos. Conclusão: O adesivo universal contendo silano promoveu os melhores valores de resistência adesiva ao bloco de resina. Para o bloco cerâmico, a aplicação adicional de silano (sem MDP) apresentou melhores resultados.

5.
RGO (Porto Alegre) ; 71: e20230007, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1431164

RESUMO

ABSTRACT Objective: To evaluate the dimensional change of edentulous models made of high density laboratory silicones at different storagetimes. Methods: A metallic master model simulating an edentulous maxilla was used. The model had projections of 1.8 cm located in the regions of canines (A and B) and molars (C and D) allowing the linear measurement of distances AB, BC, CD, DA, AC and BD. A laboratory silicone mold was made for duplication of master model in the following materials (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 and G4: Gypsum type III (control). The samples were photographed and measured using a software (Image J) at times T1 (baseline) and T2 (after one week of models fabrication). The data were statistically analyzed using Kruskal- Wallis and Dun non-parametric tests (α = 0.05). Results: The storage time influenced the behavior of the materials evaluated. All groups presented dimensional changes in both times and the group Tit95 presented the best results. Only Zet85 group showed a different behavior related to the region of the model. Conclusions: The high density laboratory silicones showed satisfactory results when compared to the gypsum group. Tit95 was the most stable material and it can be recommended as an edentulous model for total protheses.


RESUMO Objetivo: Avaliar a alteração dimensional de modelos edêntulos fabricados em silicone laboratorial de alta densidade em diferentes tempos de armazenagem. Métodos: Um modelo mestre metálico simulando uma maxila edêntula foi utilizado. O modelo possuía projeções oclusais de 1,8 cm localizadas nas regiões de caninos (A e B) e molares (C e D), permitindo a mensuração das distâncias lineares AB, BC, CD, DA, AC e BD. Um molde foi fabricado em silicone laboratorial para duplicação do modelo mestre com os seguintes materiais (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 e G4: Gesso tipo III (controle). As amostras foram fotografadas e mensuradas com auxílio de um software (Image J) nos tempos T1 (baseline) e T2 (após uma semana de confecção). Os dados obtidos foram avaliados estatisticamente utilizando os testes não paramétricos de Kruskal- Wallis e Dunn (α = 0.05). Resultados: O tempo de armazenagem influenciou o comportamento dos materiais avaliados. Todos os grupos apresentaram alterações dimensionais em ambos os temos de avaliação e o G2 apresentou os melhores resultados. Apenas o grupo G1 mostrou alteração dimensional dependente da região mensurada. Conclusão: Silicones laboratoriais de alta densidade mostraram resultados satisfatórias de alteração dimensional quando comparados ao gesso tipo III. O material Titanium 95foi o mais estável e pode ser recomendado como alternativa para a confecção de modelos edêntulos.

6.
Clinics ; 77: 100078, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1404313

RESUMO

Abstract Objectives: The aim of this study was to estimate the percentage distribution of body composition parameters for healthy people at different ages from the assessment of electrical bioimpedance. Methods: A cross-sectional study of healthy Brazilian aged 5 years and older. Were evaluated: total body fat; percent body fat; fat-free mass; percent lean mass; fat mass index; and fat-free mass index. Results: Of 1240 participants, with a median age of 27.0 years, 52.5% were female, and 73.7% were Caucasian. Most of the body composition variables were associated with age. The fat-free mass increased from youth to adult and decreased in the elderly in both sexes, with higher values in males than in females. In males, the percentage of lean mass has higher values in adolescence compared to childhood, and in adults compared to the elderly, when analyzed from the 50th percentile. In women, fat-free mass compared to adulthood, values were higher in childhood and lower in older ages. Conclusions: The study is the first to describe the Brazilian reference values for most clinical parameters of bioimpedance in percentiles stratified by different life cycles and sex. These findings can be very useful in clinical practice for health promotion and monitoring the nutritional status of the individual.

7.
Rev. Nutr. (Online) ; 35: e200323, 2022. tab
Artigo em Inglês | LILACS | ID: biblio-1406919

RESUMO

ABSTRACT Objective To evaluate the association between children and adolescents' body composition with family income. Methods Cross-sectional study, participants between 5 and 19 years were included. A standardized questionnaire assessed socioeconomic variables. The outcome variables were z-score of Body Mass Index and bioimpedance parameters (skeletal muscle mass, fat-free mass, and fat percentage) and predictor variables (age, sex, race, place of residence, father's education, birth weight and breastfeeding) were analyzed using the quantile regression model and data from the 50th percentile are presented. The tests were bidirectional and the differences were considered significant with p<0.05. Results Among the 529 participants included, 284 (53.6%) were female and the mean age was 11.41±3.9 years. The Body Mass Index z-score was the only outcome that did not show differences between sexes (p=0.158). In the crude model, lower family income was associated with lower skeletal muscle mass (Difference=-7.70; 95% CI -9.32 to -5.89), p<0.001), lower fat-free mass (Difference= -13.40; 95% CI -16.40 to -10.39, p<0.001) and the lowest percentage of fat was associated with lower family income (Difference= -5.01, 95% CI -9.91 to -0.11, p=0.027). The z-score of BMI was not associated with family income. Conclusion Family income is directly associated with lower fat-free mass, fat percentage, and skeletal muscle mass in children and adolescents.


RESUMO Objetivo Avaliar a associação entre a composição corporal de crianças e adolescentes com a renda familiar. Métodos Estudo transversal, foram incluídos participantes entre 5 e 19 anos. As variáveis socioeconômicas foram avaliadas por meio de questionário padronizado. As variáveis de desfecho foram escore Z do índice de massa corporal e parâmetros de bioimpedância (massa muscular esquelética, massa livre de gordura e percentual de gordura) e variáveis preditoras (idade, sexo, raça, local de residência, escolaridade do pai, peso ao nascer e aleitamento materno) foram analisados pelo modelo de regressão quantílica e são apresentados os dados do percentil 50. Os testes foram bidirecionais, e as diferenças foram consideradas significativas com p<0,05. Resultados Entre os 529 participantes incluídos, 284 (53,6%) eram do sexo feminino e a média de idade foi de 11,41±3,9 anos. O escore Z do índice de massa corporal foi o único desfecho que não apresentou diferenças entre os sexos (p=0,158). No modelo bruto, uma menor renda familiar foi associada a menor massa muscular esquelética (Diferença= -7,70; IC 95% -9,32 a -5,89), p<0,001), menor massa livre de gordura (Diferença= -13,40; IC 95% -16,40 a -10,39, p<0,001) e o menor percentual de gordura associou-se à menor renda familiar (Diferença= -5,01, IC 95% -9,91 a -0,11, p=0,027). O escore Z do IMC não foi associado à renda familiar. Conclusão A renda familiar está diretamente associada à menor massa magra, ao percentual de gordura e à massa muscular esquelética em crianças e adolescentes.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Adulto , Adulto Jovem , Composição Corporal/fisiologia , Renda , Índice de Massa Corporal , Criança , Estudos Transversais , Adolescente , Fatores Sociodemográficos
8.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385799

RESUMO

ABSTRACT: This study aimed to compare the trueness and precision of physical models manufactured chairside (intraoral scanner and 3D printed) or by plaster models obtained using impression with alginate or addition silicone. A full- arch stainless steel die was impressed to obtain ten physical models for each group. The models were measured in a stereomicroscope, considering four linear distances. To assess the precision accuracy, an analysis of the measurement variability was carried out, identified by the coefficients of variation and by the Levene's test to compare the groups. To analyze trueness, the data average was subtracted from the database and compared considering alpha as 5 %. Considering precision, the higher dispersion of data occurred in the models obtained with silicone impression. And for trueness, Kruskal Wallis and Dunn tests results did not indicate differences between the groups in the anteroposterior linear distances (p> 0.05). Only in anterior transverse distance obtained through TRIOS (0.31 mm), it presented lower accuracy compared to the models from silicone impression (0.13 mm); however, at transverse posterior distance, the models from silicone impression showed the lowest accuracy (p 0.05). The physical dental models obtained by digital and analog workflows showed acceptable dimensional accuracy expressed by high precision and trueness. There is no difference between the evaluated intraoral scanner systems and the impression materials for the full-arch impression.


RESUMEN: Este estudio tuvo como objetivo comparar la veracidad y precisión de modelos físicos fabricados en la clínica dental (escáner intraoral e impreso en 3D) o por modelos de yeso obtenidos mediante impresión con alginato o silicona de adición. Una matriz de acero inoxidable de arco completo fue impresa para obtener diez modelos físicos para cada grupo. Los modelos se midieron en un estereomicroscopio, considerando cuatro distancias lineales. Se realizó un análisis de la variabilidad de la medida para evaluar la precisión, identificada por los coeficientes de variación y por la prueba de Levene para comparar los grupos. Para analizar la veracidad, el promedio de los datos se restó de la base de datos y se comparó considerando alfa como 5 %. Considerando la precisión, la mayor dispersión de datos ocurrió en los modelos obtenidos con impresión de silicona. Y para la veracidad, los resultados de las pruebas de Kruskal Wallis y Dunn no indicaron diferencias entre los grupos en las distancias lineales anteroposteriores (p> 0,05). Solo en la distancia transversal anterior obtenida mediante TRIOS (0,31 mm) presentó menor precisión en comparación con los modelos de impresión de silicona (0,13 mm); sin embargo, la distancia transversal posterior, los modelos de impresión de silicona mostraron la menor precisión (p 0,05). Los modelos dentales físicos obtenidos mediante flujos de trabajo digitales y analógicos mostraron una precisión dimensional aceptable expresada por alta precisión y veracidad. No se observó diferencia entre los sistemas de escáner intraoral evaluados y los materiales de impresión para la impresión de arco completa.

9.
J. pediatr. (Rio J.) ; 97(1): 75-79, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1154722

RESUMO

Abstract Objective: The aim of the present study was to evaluate the agreement between the most used skinfold thickness equations with multi-frequency bioimpedance analysis in the prediction of body fat levels in children. Method: A cross-sectional study of healthy Brazilian community-dwelling individuals. The anthropometric assessment included height, body mass, arm circumference, and waist circumference. The percentage of body fat was obtained by measuring skinfold thickness equations and using bioimpedance analysis, and skinfold thickness was measured using a scientific skinfold caliper. Bland-Altman plot analysis was used to verify the agreement between the methods. Results: There were 439 children and adolescents evaluated, with a mean age of 11.6 ± 3.7 years. The mean body fat by bioimpedance analysis was 22.8% ± 10.4%, compared to 22.4% ± 8.8% by Slaughter (1), 20.4% ± 9.2% by Slaughter (2), 19.6% ± 4.4% by Goran, and 24.7% ± 10.0% by Huang equations. Bland-Altman plot analysis revealed limits of agreement greater than 8% between the bioimpedance analysis approach and equations, exceeding the clinically acceptable limit predefined a priori. None of the equations had good agreement with bioimpedance analysis. Conclusion: It was concluded that skinfold thickness and bioimpedance analysis should not be used interchangeably in children and adolescents.


Assuntos
Humanos , Criança , Adolescente , Composição Corporal , Tecido Adiposo , Dobras Cutâneas , Brasil , Antropometria , Estudos Transversais
10.
Braz. dent. j ; 32(1): 53-58, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1180728

RESUMO

Abstract The endodontic revascularization may be an alternative treatment for necrotic immature teeth, however, several treatment steps may cause tooth discoloration. This study evaluated the use of three calcium silicate-based cements with different radiopacifying agents on the color alteration (∆E) of extracted premolars after simulation of revascularization. Forty single rooted extracted premolars were shaped with #1-6 gates Glidden drills, rinsed with sodium hypochlorite, and filled with fresh human blood. Three calcium silicate-based cements with different radiopacifying agents (bismuth oxide - CSBi, calcium tungstate - CSW, and zirconium oxide - CSZr) were applied over the blood clot (n=10). The control group received the application of a temporary zinc oxide-based cement (TFZn) (n=10). ∆E was measured with a spectrophotometer, using the L*a*b* color system of the International Commission on Illumination (CIELab), in different times: prior to the preparation of the access cavity (t0); right after treatment (t1); and after one (t2), two (t3), three (t4) and four (t5) months. The tooth site for color evaluation was standardized by silicon matrix, the color reading was performed 3 times per tooth, and the teeth were stored in 37º water between evaluations. ∆E, whiteness (WID index) and yellowness (b*) were evaluated. Data were subjected to one-way ANOVA and repeated measures ANOVA, followed by Tukey's post hoc test (α=0.05). All groups were similar in ∆E1 (t0-t1). The ∆E was the lowest and constant in the control group. In all evaluation times, CSBi presented the highest ∆E (p<0.01). CSW and CSZr were similar in all evaluated times and presented intermediate ∆E values. WID index from CSBi and CSW presented more distancing from 'white' reference. CSBi presented the greatest decrease in yellowness (b* value). The cement containing bismuth oxide presented the highest color alteration values. All tested calcium silicate-based cements presented clinically perceptible discoloration. Calcium tungstate and zirconium oxide may be used as alternative radiopacifiers to decrease tooth discoloration after endodontic tooth revascularization.


Resumo A revascularização endodôntica pode ser um tratamento alternativo para dentes imaturos necrosados, porém, várias etapas do tratamento podem causar alteração de cor dental. Este estudo avaliou o uso de três cimentos a base de silicato de cálcio com diferentes agentes radiopacificadores na alteração de cor (∆E) de pré-molares extraídos após a simulação de revascularização. Quarenta pré-molares unirradiculares extraídos foram conformados com brocas gates glidden #1-6, irrigados com hipoclorito de sódio, e preenchidos com sangue humano fresco. Três cimentos a base de silicato de cálcio com diferentes agentes radiopacificadores (óxido de bismuto - CSBi, tungstato de cálcio - CSW, e óxido de zircônio - CSZr) foram aplicados sobre o coágulo sanguíneo (n=10). O grupo controle recebeu a aplicação de um cimento temporário a base de óxido de zinco (TFZn) (n=10). ∆E foi medida com um espectrofotômetro, utilizando o sistema de cor L*a*b* da International Commission on Illumination (CIELab), em tempos diferentes: previamente ao preparo da cavidade de acesso (t0); logo após o tratamento (t1); e após um (t2), dois (t3), três (t4) e quatro (t5) meses. O local do dente para a avaliação de cor foi padronizado por uma matriz de silicone, a leitura da cor foi realizada 3 vezes por dente, e os dentes foram armazenados em água a 37ºC entre as avaliações. ∆E, 'clareamento' (índice WID) e tom amarelado (b*) foram avaliados. Os dados foram submetidos ao teste de ANOVA um fator e teste ANOVA de medidas repetidas, seguidos pelo teste post hoc de Tukey (α=0,05). Todos os grupos foram semelhantes em ∆E1 (t0-t1). A ∆E foi menor e constante no grupo controle. Em todos os tempos de avaliação, CSBi apresentou os maiores valores de ∆E (p<0.01). CSW e CSZr foram semelhantes em todos os tempos avaliados e apresentaram valores intermediários de ∆E. O índice WID de CSBi e CSW se distanciaram mais da referência 'branco'. CSBi apresentou maior diminuição no tom amarelado (valor de b*) os outros grupos. O cimento contendo óxido de bismuto apresentou os maiores valores de alteração de cor. Todos os cimentos testados apresentaram alteração de cor clinicamente perceptível. O tungstato de cálcio e óxido de zircônio podem ser usados como radiopacificares alternativos para a diminuição da alteração de cor dental após o processo de revascularização endodontica.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular , Descoloração de Dente , Óxidos , Silicatos , Compostos de Cálcio , Compostos de Alumínio , Cimentos Dentários , Combinação de Medicamentos
11.
Braz. oral res. (Online) ; 34: e096, 2020. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1132722

RESUMO

Abstract Regulatory T (Treg) cells can suppress antitumor immune response, but little is known about possible age-related differences in the number of these cells in the microenvironment of oral tongue squamous cell carcinoma (OTSCC). The aim of this study was to determine the number of FoxP3+ Treg cells in the microenvironment of OTSCC in young (≤ 45 years) and older (≥ 60 years) patients, and to correlate the findings with clinicopathological parameters (sex, tumor size/extent, regional lymph node metastasis, clinical staging, and histopathological grade of malignancy). Forty-eight OTSCCs (24 diagnosed in young patients and 24 diagnosed in older patients) were selected. Lymphocytes exhibiting nuclear immunopositivity for FoxP3 were quantified at the tumor invasive front and the results were analyzed statistically using the non-parametric Mann-Whitney test. FoxP3+ lymphocytes were observed in all cases assessed. The number of FoxP3+ lymphocytes in OTSCC tended to be higher in older patients (p = 0.055). Analysis of OTSCC in males and in early clinical stages revealed a higher number of Treg cells in older patients than in young ones (p < 0.05). In older patients, the number of Treg cells tended to be higher in smaller tumors (p = 0.079). Tumors with intense inflammatory infiltrate exhibited a larger number of Treg cells, both in young (p = 0.099) and older patients (p = 0.005). The results suggest a greater participation of Treg cells in immunoinflammatory responses in the microenvironment of OTSCC in older patients, particularly in males and in early stages.


Assuntos
Humanos , Masculino , Neoplasias da Língua , Carcinoma de Células Escamosas , Linfócitos T Reguladores , Fatores de Transcrição Forkhead , Microambiente Tumoral , Estadiamento de Neoplasias
12.
Braz. oral res. (Online) ; 33: e085, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019611

RESUMO

Abstract The aim of this study was to evaluate the immunoexpression of human leukocyte antigen-DR (HLA-DR) in actinic cheilitis (AC) and lower lip squamous cell carcinoma (LLSCC), and to correlate the findings with clinical (tumor size/extent, regional lymph node metastasis, and clinical stage) and histopathological (grade of epithelial dysplasia and inflammatory infiltrate for AC and histopathological grade of malignancy for LLSCC) parameters. Twenty-four AC and 48 LLSCC cases (24 with regional nodal metastasis and 24 without regional nodal metastasis) were selected. The scores of immunopositive cells for HLA-DR in the epithelial component of the lesions were assessed and the results were analyzed statistically using the nonparametric Mann-Whitney test. Epithelial expression of HLA-DR was observed in only five (20.8%) cases of AC (two low-grade and three high-grade lesions), with a very low median score of immunopositivity. By contrast, expression of HLA-DR was found in most LLSCC (97.9%), with a relatively high median score of positive cells. The score of HLA-DR-positive cells tended to be higher in tumors with regional lymph node metastasis, tumors in advanced clinical stages, and low-grade tumors, but the difference was not statistically significant (p > 0.05). In addition, there was a tendency towards higher expression of HLA-DR in highly/moderately keratinized tumors, and tumors with little/moderate nuclear pleomorphism (p > 0.05). The results suggest a potential role of HLA-DR in lip carcinogenesis, particularly in the development and progression of LLSCC. The expression of this protein can be related to the degree of cell differentiation in these tumors.


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Labiais/imunologia , Antígenos HLA-DR/imunologia , Queilite/imunologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/imunologia , Neoplasias Labiais/patologia , Neoplasias Labiais/secundário , Queilite/patologia , Gradação de Tumores , Carcinogênese/imunologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/secundário , Inflamação/patologia , Metástase Linfática/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias
13.
Araçatuba; s.n; 2019. 96 p. tab.
Tese em Português | LILACS, BBO | ID: biblio-1444977

RESUMO

A qualidade de vida é a percepção do indivíduo sobre sua posição na vida e em relação aos seus objetivos, expectativas, padrões e preocupações representando seu grau de satisfação. Cuidar de pacientes com Sídrome de Down (SD) demanda tarefas complexas, delicadas e sofridas que somadas as responsabilidades diárias, podem gerar um impacto na qualidade de vida. Além disso, toda sobrecarga, pode causar estresse social e trazer sentimentos de ansiedade e depressão, em longo prazo, ao cuidador de um portador da SD. Assim, o objetivo foi avaliar a qualidade de vida, ansiedade, estresse e depressão de cuidadores de pacientes com ou sem síndrome de Down. O estudo foi conduzido com uma amostra de 144 participantes, que serão divididos entre dois grupos denominados GC (Grupo Controle) e GSD (Grupo Síndrome de Down). No GC, participou do estudo cuidadores de crianças com desenvolvimento normal de uma escola pública, numa faixa etária de 4 a 8 anos e no GSD, participou do estudo cuidadores principais de pacientes com SD, numa faixa etária de 4 a 30 anos de idade. Para coleta de dados foram utilizados 5 questionários para identificação do cuidador, avaliação da qualidade de vida (WHOQOL-Bref), avaliação de depressão (BDI), avaliação de ansiedade (BAI) e avaliação de estresse (LIPP). Para a análise dos dados foram identificadas categorias referentes ao perfil do cuidador, e foi utilizado teste Quiquadrado com post hoc Bonferroni modificado com nível de significância de p ≤ 0,05, para comparação entre os grupos e os testes de correlação de Rank e Pearson. Não houve diferença significativa entre os grupos na avaliação do BDI. Houve correlação maior e significativa do nível de ansiedade com os cuidadores do grupo C. A intensidade dos sintomas físicos de estresse foi significativamente maior no grupo SD, no qual 37,8% estavam na fase de exaustão do estresse. Na avaliação da qualidade de vida, o grupo SD teve correlação significativa menor referente ao domínio psicológico do que o grupo C e maior referente ao domínio do meio ambiente do que o grupo C. No grupo SD, houve correlação positiva entre sintomas físicos do estresse e o grau de dependência do portador de SD, (Correlação de Pearson=0,23; p=0,04). Também foi mostrado que a auto avaliação da qualidade de vida foi melhor entre os cuidadores de SD que tinham uma maior renda familiar (correlação de Pearson=0,53; p=0.02). Assim conclui-se que os cuidadores de pessoas com SD apresentaram piores sintomas de estresse físico e pior qualidade de vida no domínio psicológico do que os cuidadores de crianças sem SD. Os sintomas de estresse físico estão relacionados com o maior grau de dependência do portador de SD, enquanto que a qualidade de vida dos cuidadores de SD tem relação direta com uma maior renda familiar(AU)


Quality of life is the individual's perception of their position in life and in relation to their goals, expectations, standards and concerns representing their degree of satisfaction. Caring for patients with Down's Syndrome (DS) demands complex, delicate and painful tasks that, added to the daily responsibilities, can have an impact on quality of life. In addition, any overload can cause social stress and bring long-term feelings of anxiety and depression to the caregiver of a patient with DS. Thus, the objective was to assess the quality of life, anxiety, stress and depression of caregivers of patients with or without Down syndrome. The study was conducted with a sample of 144 participants, who will be divided between two groups called GC (Control Group) and GSD (Down Syndrome Group). In the CG, caregivers of children with normal development in a public school, aged 4 to 8 years, participated in the study and in the GSD, the main caregivers of patients with DS, aged 4 to 30 years, participated in the study. For data collection, 5 questionnaires were used to identify the caregiver, assess quality of life (WHOQOL-Bref), assess depression (BDI), assess anxiety (BAI) and assess stress (LIPP). For data analysis, categories related to the caregiver's profile were identified, and a Chi-square test with modified post-hoc Bonferroni was used, with a significance level of p ≤ 0.05, for comparison between groups and Rank and correlation tests. Pearson. There was no significant difference between groups in the BDI assessment. There was a greater and more significant correlation of the level of anxiety with the caregivers of group C. The intensity of the physical symptoms of stress was significantly higher in the DS group, in which 37.8% were in the phase of stress exhaustion. In assessing quality of life, the SD group had a significantly lower correlation with regard to the psychological domain than group C and a greater correlation with the environment domain than group C. In the SD group, there was a positive correlation between physical symptoms of stress and the degree of dependence of the DS patient, (Pearson's correlation = 0.23; p = 0.04). It was also shown that selfrated quality of life was better among DS caregivers who had a higher family income (Pearson's correlation = 0.53; p = 0.02). Thus, it is concluded that caregivers of people with DS had worse symptoms of physical stress and worse quality of life in the psychological domain than caregivers of children without DS. Symptoms of physical stress are related to a higher degree of dependence on the DS patient, while the quality of life of DS caregivers is directly related to a higher family income(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estresse Psicológico , Inquéritos e Questionários
14.
Braz. j. oral sci ; 18: e191505, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1095165

RESUMO

Aim: In dental implant treatment, there is a demand for mechanically stronger implants. Despite the existence of several studies showing the clinical success of narrow diameter implants, most of them are based on pure titanium (cpTi) alloys. There is a few clinical evidences of the success rate of titanium-zirconium (TiZr) narrow diameter implants. The aim of this study was to evaluate the stress distribution in the peri-implant area of narrow diameter cpTi and TiZr implants under axial and oblique loads. Methods: Photoelastic models were produced using epoxy resin (PL2, Vishay Precision Group) from a master model. The implants (cpTi and TiZr; Straumann AG) had 3.3 mm in diameter and 12 mm in height. Loads of 100 N and 200 N were applied to the abutment at angles of 0° (axial), 10°, 20°, and 30° (oblique). A circular polariscope (Eikonal) was used under dark field white-light configuration. The isochromatic fringes were analyzed in the peri-implant region in 5 areas, using ASTM table with isochromatic fringes; cervical-mesial, cervical-distal, mid-mesial, mid-distal and apical. Results: In general, under axial and oblique loads, the stress in the TiZr implant was lower than in the cpTi implant. The load of 200 N produced the highest stress values in cpTi and TiZr implants. In both implants and loads, the fringes were located more in apical area at all angles evaluated. Conclusion: It can be concluded that for small implants, the load inclination and intensity change the pattern of stress distribution and the cpTi implant exhibited the highest peri-implant stress


Assuntos
Estresse Mecânico , Titânio , Implantes Dentários , Análise do Estresse Dentário
15.
Artigo | IMSEAR | ID: sea-192162

RESUMO

This study aims to systematically evaluate the effects of traumatic occlusion on the periodontal tissue of rats. The set of questions to be answered were–Can traumatic occlusion acting on a healthy and an unhealthy periodontium cause periodontal destruction? Design: The protocols for systematic review were all developed, following the Preferred Reporting Items for Systematic reviews and Meta-Analyses statement and applied to animal research. Reporting of In vivo experiment guidelines for reporting animal research to assess the risk of bias of the studies. Materials and Methods: A literature search was conducted using MEDLINE through PubMed and manual search from the reference lists of main articles related to the theme. Results: This search strategy identified 65 references, of which 33 were considered inappropriate. The full texts of 32 articles were read, 31 of which did not meet the eligibility criteria and were excluded. The final selection included 1 article for which data was extracted for further evaluation. The article included shows a strongest reaction in the periodontium in front of a secondary occlusal trauma as inflammation and apical migration of the junctional epithelium, bone degradation, and decrease in the quantity of collagen fiber. However, primary occlusal trauma also presents these alterations, with the exception of apical migration of the junctional epithelium. Conclusions: Although only one study was included in the systematic review of traumatic occlusion, there is some evidence from experimental studies on animals that shows a coherent picture of the effects of traumatic occlusion on the periodontium. However, new studies are needed to fully answer the questions posed by this systematic review.

16.
Braz. oral res. (Online) ; 32: e7, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889497

RESUMO

Abstract The aim of this study is to evaluate the action of paramonochlorophenol associated with Furacin followed by calcium hydroxide (CH) dressing in the control of inflammatory root resorption in cases of immediate tooth replantation with delayed endodontic treatment. A total of 28 incisors of 3 male dogs were extracted and replanted after 15 minutes, and randomly divided into 3 groups: Group I (n = 8) - endodontic treatment was performed before the extraction and replantation; Group II (n = 10) - endodontic treatment was performed 30 days after replantation and the root canal was filled with CH dressing; Group III (n = 10) - endodontic treatment was performed 30 days after replantation and root canals received temporary medication of paramonochlorophenol-Furacin followed by CH dressing. The animals were euthanized 90 days after replantation. The histomorphological events analyzed at the epithelial reattachment site were the intensity and extent of acute and chronic inflammatory processes, periodontal ligament (PDL) organization, the intensity and extent of acute and chronic inflammatory processes in the PDL space, root resorption, bone tissue, and ankylosis. Data were submitted to the Wilcoxon Signed Ranks Test for group comparison (α = 5%). In Groups I, II and III the periodontal ligament was regenerated and most of the resorption areas were repaired by newly formed cementum. The depth and extent of root resorption were significantly higher in Group II than in Group III. The use of paramonochlorophenol-furacin followed by CH dressing was more effective in controlling inflammatory root resorption after immediate tooth replantation.


Assuntos
Animais , Masculino , Cães , Reabsorção da Raiz/prevenção & controle , Reimplante Dentário/métodos , Clorofenóis/farmacologia , Dente não Vital/tratamento farmacológico , Anti-Infecciosos Locais/farmacologia , Nitrofurazona/farmacologia , Ligamento Periodontal/efeitos dos fármacos , Ligamento Periodontal/patologia , Materiais Restauradores do Canal Radicular/farmacologia , Tratamento do Canal Radicular/métodos , Reabsorção da Raiz/patologia , Fatores de Tempo , Raiz Dentária/efeitos dos fármacos , Raiz Dentária/patologia , Hidróxido de Cálcio/farmacologia , Distribuição Aleatória , Reprodutibilidade dos Testes , Resultado do Tratamento , Dente não Vital/patologia , Ilustração Médica
17.
Braz. oral res. (Online) ; 32: e53, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952144

RESUMO

Abstract This in vitro study evaluated the fatigue strength of different ceramic materials indicated for monolithic restorations. Disc-shaped specimens were made according to ISO 6872 from five different ceramic materials: feldspathic ceramic (FC), polymer-infiltrated ceramic network (PIC), lithium disilicate glass-ceramic (LD), zirconia-reinforced lithium silicate glass-ceramic (ZLS), and high translucent tetragonal zirconia polycrystals doped by yttrium (YZ-HT). After obtaining the mean of each material (n = 5) from monotonic load-to-failure tests, specimens (n = 20) were subjected to fatigue tests (staircase method) using a biaxial flexural setup (piston-on-three-balls), to determine the fatigue strength. The parameters used for fatigue tests were: 100,000 cycles at 10 Hz, initial load of ~ 60% of mean load-to-failure, and step size of 5% of the initial load (specific for each ceramic material). Kruskal-Wallis and Bonferroni's test (α = 0.05) were used to analyze the fatigue strength data. Fatigue strength (MPa) of the materials was statistically different among each other as follows: YZ-HT (370.2 ± 38.7) > LD (175.2 ± 7.5) > ZLS (152.1 ± 7.5) > PIC (81.8 ± 3.9) > FC (50.8 ± 1.9). Thus, it can be concluded that, in terms of fatigue, high translucent polycrystalline zirconia is the best choice for monolithic restorations as it bears the highest load before cracking/fracturing.


Assuntos
Estresse Mecânico , Cerâmica/química , Desenho Assistido por Computador , Falha de Restauração Dentária , Valores de Referência , Propriedades de Superfície , Resistência à Tração , Zircônio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Maleabilidade , Porcelana Dentária/química , Análise do Estresse Dentário
18.
Braz. oral res. (Online) ; 32: e32, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889472

RESUMO

Abstract This study aimed to investigate slow crack growth (SCG) behavior of a zirconia ceramic after grinding and simulated aging with low-temperature degradation (LTD). Complementary analysis of hardness, surface topography, crystalline phase transformation, and roughness were also measured. Disc-shaped specimens (15 mm Ø × 1.2 mm thick, n = 42) of a full-contour Y-TZP ceramic (Zirlux FC, Amherst) were manufactured according to ISO:6872-2008, and then divided into: Ctrl - as-sintered condition; Ctrl LTD - as-sintered after aging in autoclave (134°C, 2 bar, 20 h); G - ground with coarse diamond bur (grit size 181 μm); G LTD - ground and aged. The SCG parameters were measured by a dynamic biaxial flexural test, which determines the tensile stress versus stress rate under four different rates: 100, 10, 1 and 0.1 MPa/s. LTD led to m-phase content increase, as well as grinding (m-phase content: Ctrl - 0%; G - 12.3%; G LTD - 59.9%; Ctrl LTD - 81%). Surface topography and roughness analyses showed that grinding created an irregular surface (increased roughness) and aging did not promote any relevant surface change. There was no statistical difference on surface hardness among different conditions. The control group presented the lowest strength values in all tested rates. Regarding SCG, ground conditions were less susceptible to SCG, delaying its occurrence. Aging (LTD) caused an increase in SCG susceptibility for the as-sintered condition (i.e. G < G LTD < Ctrl < Ctrl LTD).


Assuntos
Temperatura Baixa , Ítrio/química , Zircônio/química , Análise de Variância , Análise do Estresse Dentário , Testes de Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Difração de Raios X
19.
Artigo em Inglês | IMSEAR | ID: sea-183315

RESUMO

Context: A better understanding of the relation between traumatic dental occlusion and periodontal changes is needed. Aims: This study aimed to evaluate the pattern of osteoclastic activity in the periodontal bone in front of the traumatic dental occlusion in rat molars. Patients and Methods: Traumatic dental occlusion (TO) was induced in twenty rats, which were sacrificed after periods of 2, 5, 7, and 14 days. Transversal histological sections of both jaws were stained with tartrate‑resistant acid phosphatase and hematoxylin and eosin. Mann– Whitney U‑test was used for group comparison, and Pearson’s correlation test was applied for the number of osteoclasts and bone area (BA). Results: Traumatic dental occlusion caused an increase in the number of osteoclasts in the bone of the upper and lower right first molar from days 2–5 to 2–14, respectively. In the TO groups, the number of osteoclasts on the lamina dura and in the center of the alveolar bone septum, respectively, increased almost 4‑fold and 9‑fold in the lower jaw; and 3‑fold and 5‑fold in the upper jaw, during all periods. In the TO groups, the BA of the alveolar bone septum was substantially reduced. There was a negative correlation between the number of osteoclasts and BA in both jaws during all experimental periods. Conclusions: Traumatic dental occlusion increases osteoclast activity in the alveolar lamina dura and in the center of alveolar bone and stimulates a higher degradation in the center of the alveolar bone septum.

20.
Clín. int. j. braz. dent ; 12(2): 186-191, abr.-jun. 2016. tab
Artigo em Português | LILACS, BBO | ID: biblio-1218

RESUMO

O selamento dentinário imediato é uma técnica que visa à aplicação de um sistema adesivo imediatamente após a confecção do preparo dental e antes do procedimento de moldagem para a confecção de restaurações indiretas. Observou-se, através de revisão de literatura, que esta abordagem traz benefícios na resistência de união a cimentos resinosos e na prevenção à sensibilidade pós-operatória de dentes preparados para restaurações indiretas. Diversos sistemas adesivos, assim como cimentos resinosos, com diferentes formulações e técnicas de utilização, estão disponíveis no mercado. Sob esse enfoque, foi proposto um protocolo de utilização da técnica de selamento dentinário imediato para os diferentes tipos de restaurações indiretas(AU)


The immediate dentin sealing is a technique that comprises the application of an adhesive system immediately after tooth preparation and before impression taking for the fabrication of indirect restorations. Based on a literature review, it was observed that this approach has benefits regarding bonding strength of dentin to resin cements and decreases the post operatory sensitiveness of teeth prepared for indirect restorations. A number of adhesive systems, as well as resin cements, with different formulations and application protocols are available. Based on the available information, it was proposed a protocol for the application of the immediate dentin sealing technique for different types of tooth preparation(AU)


Assuntos
Sensibilidade da Dentina , Adesivos Dentinários , Cimentos Dentários , Restauração Dentária Temporária , Selantes de Fossas e Fissuras , Guias como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA